A contact is necessary between a patient’s mucous membranes or sterile tissue and any surgical tool or medical instrument during all the invasive procedures. Infection is big risk while undertaking such procedures because of the transfer of pathogenic microbes leading to infection. If the reusable medical equipment is not properly sterilized or disinfected, it can cause a breach risk of host barriers. The level of sterilization or disinfection depends upon the needed use of the equipment: non-critical equipment for example stethoscope having contact with intact skin; semi-critical equipment for example endoscopes having contact with mucous membranes; and critical equipment for example surgical tools having contact with the sterile tissue requires low disinfection, high disinfection and sterilization respectively. Sterilization and high-level of disinfection should be done after cleaning. When choosing the process of sterilization or disinfection, advantages and disadvantages of those processes should be considered by the user. Practices of sterilization and disinfection would be improved in the health care facilities if these recommendations are followed as a result of which infections would be reduced.
During 1996, almost 46,500,000 processes of surgery and large number of invasive medical processes took place in the United States. For instance, almost every year 5 million gastrointestinal endoscopies are practiced in United States. Every process such as this uses medical instrument or surgical tool which has contact with the mucous membranes or sterile tissue of the patient. One of the major risks associated with such processes is infection which can begin because of induction of pathogenic microbes. For instance, if the instrument is not properly sterilized or disinfected, it can lead to contaminated instruments through transmission from patient-to-patient such as contaminated bronchoscopes or Mycobacterium tuberculosis.
For ensuring that the surgical tools and medical devices do not transfer any infectious pathogens to the patients, it is important to use sterilization and disinfectants practices for sterilization and disinfection of instruments respectively. Based on the usage of each item, health care policies should mention cleaning, sterilize or disinfection processes for the items as it is not important to sterilize all the items related to patient-care.
Many countries have conducted studies in which the guidelines for sterilization and disinfection are not followed properly which have led to many occurrences of infections.
This article will discuss a pragmatic approach to the use and selection of practices of sterilization and disinfection based on the well-designed studies’ results which assess the efficacy through laboratory research and effectiveness through clinical investigations of the said procedures.
A RATIONAL APPROACH TO DISINFECTION AND STERILIZATION
A rational approach to the sterilization and disinfection of patient-care tools and items was established by Spaulding almost 35 years ago. During the planning process for sterilization and disinfection, this approach has been widely used by the professionals and other infection-control personnel as it presents a logical and clear procedure which has been refined over time. According to this approach, if the tools and instruments of patient-care are categorized in three groups, the nature of disinfection could be understood more – non critical, semi critical and critical – which is based on the level of infection risk associated with the usage of items. Documents called ‘Guideline for Disinfection and Sterilization in Healthcare Facilities’ and ‘Guidelines for Environmental Infection Control in Health Care Facilities’ use this terminology as given by the Centers for Disease Control and Prevention (CDC).
Critical items
If item is polluted with microorganism such as bacterial spores it leads to some critical objects and has got high risk of getting infected. It is important to sterilize the objects which penetrate into sterlie tissue or the vascular system and is decisive to sterilize them with care. If it is not handled properly it can cause transmission of disease because of the microbial contamination. Surgical instruments, implants, cardiac and urinary catheters, and ultrasound prod which are used in cavities of sterile bodies and are included in this category. Steam sterilization should be used by these items to sterilize or to purchase as sterile. There are various methods for sterilization when the item becomes heat sensitive. Ethylene oxide (ETO) or hydrogen peroxide gas plasma or liquid chemical sterilants can be used as a method to prevent items. Various germicides are categorized as chemical sterilants and are shown in tables 1 and 2. Formulations may vary and may include 2.4% glutaraldehyde with the formulation base, 1.12% of glutaraldehyde with 1.93% phenol/phenate, 7.5% of stabilized hydrogen peroxide, 7.35% of hydrogen peroxide with 0.23% peracetic acid, 0.2% of peracetic acid, and 1.0% of hydrogen peroxide with 0.08% peracetic acid. The range for this exposure time is between 3-12h and has an exception of peracetic acid of 0.2% with 12 minutes time of sporicidal and at 50 to 56 centigrades. A reliable method for sterilization is the using of liquid chemical sterilants but there needs to be treatment of cleaning precedes which helps in removing organic and inorganic material but for this they need to follow guidelines properly regarding concentration and the contact time along with temperature and pH. Sterilizing the devices with sterliants of liquid chemical leads to few other constraints as that of having difficulty in wrapping of devices. While processing is done the devices cannot be wrapped in the sterilant of liquid chemical. Therefore, it is not possible to sterilize after the processing and in the period of storage. Moreover, it is required to rinse the devices with water after they have been exposed to the liquid chemical sterilant. While keeping such constraints in mind regarding the liquid chemical sterilant especially in nonautomated reprocessor the use of such sterilant should be controlled for reprocess of the critical devices which are primarily heat sensitive and contrary with various other methods of sterilization. Semicritical items. The items which appear to be in contact with the membrances of mucous and non intact skin are called semicritical items. In this category equipments used for anesthesia, respiratory-therapy, endoscopes, anorectal manometry catheters, laryngoscope blades, diaphragm-fitting rings, and esophageal manometry probes are incorporated. There should be no microorganisms like fungi, mycobacteria, viruses, and bacteria in such medical devices. However there may be small little bacterial spores present.
Bacterial spores help in resisting to the infections of whole mucous membrances and gastrointestinal tract. However, they are vulnerable to some other organisms like mycobacteria, viruses and other bacteria’s. A high level of disinfection is needed for semicritical items by the use of chemical disinfectants. The US Food and Drug Administration (FDA) have cleared some of the peroxide like glutaraldehyde, chlorine
,ortho-phthalaldehyde (OPA), peracetic acid with hydrogen peroxide and hydrogen peroxide. Moreover, according to tables 1 and 2 there are high level of disinfectants especially when guidelines are followed regarding the effective germicidal procedures. The time duration for exposure of high level of disinfectants may vary ranging from 10 minutes to 45 minutes at a temperature of 20 to 25 centigrade. With the use of ineffective disinfectants an eruption of infection keeps on occurring and also includes alcohol, iodophor and overdiluted glutaraldehyde for the use of high level of disinfection. Chemical compatibility needs to be measured for the items which are disinfected when specific item is used for taking care of the patient. An example shows that cosmetic and functional changes have been seen by the use of compatibility testing which was conducted by the Olympus America with 7.5% of hydrogen peroxide. These changes were seen in the tested endoscopes and likewise it is not supported by the Olympus America to use products which contain hydrogen peroxide especially with peracetic acid. The reason for this is the damages occurred due to the cosmetic and functional changes.
Any semi critical products that came in contact with mucous membranes present in the respiratory and gastrointestinal organs need to be thoroughly washed up with clean, sterile water, or water direct from the tap, which is to be followed by a rinsing from alcohol. The possibility of contamination occurring or a air drying mark being left behind is reduced with the help of the alcohol rinse as it cures and sterilizes the wet area where there can be a possible formation of bacteria. Following this rinsing process, the items should be kept away in a dry place where they can be prevented from being contaminated or damaged in any way. There is no restriction to use only sterilized water or filtered water for the semi critical equipment that are used with the mucous membrane in the rectal probes and anoscopes or in the vaginal probes. These items can be washed with plain tap water. (e.g., anoscopes or rectal probes ) or vagina (e.g., vaginal probes)
Noncritical items.
The equipment that comes in contact with the part that has intact skin is known as non critical items. This equipment is not used in areas of the mucous membrane. Intact skin acts as a successful barricade against the microorganisms, thus it is not critical to ensure the sterility of these equipments. Bedpans, blood-pressure cuffs, crutches, bedrails, linens, bedside tables, patient furniture and the floor are some examples of items that can be classified as non critical. The advantage gained with the non critical items is the fact that they can be decontaminated at their own location after they have been used rather than having to carry them to a central area where they can be sterilized again. This is not the case with critical and semi critical items. There is no evidence of infections and diseases being transmitted to the patients through the use of non critical products when they are used with the mucous membranes or with the nonintact skin areas.
These items (e.g., bedside tables or bed rails) may however be a part of transmitting secondary germs or diseases via contamination through the hands of the hospital staff and workers or by coming in contact with the equipment that will later come in contact with the patients. The following table outlines some of the disinfectants that can be used with this non critical equipment so as to reduce the transmission risk. The time span of the disinfectants is approximately a minute or more.
CURRENT ISSUES IN DISINFECTION ND STERILIZATION
Reprocessing of endoscopes.
Endoscopes are used by the physicians to detect and then treat various diseases. Though endoscopes are effective medical tools and a beneficial tool in the modern science and their use has rarely been linked to any occurrence of an infection, the care-related eruption of infection has frequently been associated to contaminated endoscopes as compared to any other medical tool. In order to avoid the health-related infections, all the heat-sensitive endoscopes such as bronchoscopes, gastrointestinal endoscopes and nasopharyngoscopes should be cleaned and at least should be disinfected at high levels after each use. Although a small number of bacterial spores may be present when there are a good number of spores present, disinfecting at high level destroys all microorganisms.
Recommendations for disinfecting and cleaning the endoscopes are published therefore should be followed closely. Audit results have shown that the guidelines are not being followed on reprocessing by the personnel, thus sadly there is a continuous eruption of infections. Individuals who are responsible for reprocessing should be required to undergo initial as well as annual competency testing in order to be sure that the personnel who should reprocess are properly taught.
After performing leak testing, there are 5 steps that should be followed to disinfect endoscope or to sterilize it with a sterilant liquid chemical or disinfecting at high levels. The first step involves cleaning. Internal as well as external surfaces should be cleaned mechanically which should also include brushing internal channels and with an enzymatic cleaner, flushing each internal channel with water. The second step is disinfecting. Submerge the disinfectant endoscope in a high level disinfectant or a chemical sterilant. Next, suffuse the disinfectant, in such a way that all the air pockets are eliminated and contact with the germicide is assured with the internal channels, to all reachable channels i.e. biopsy/suction channel as well as the water/air channel and then finally disclose the endoscope for septic products as per the recommended time. The third step is rinsing. The endoscope should be rinsed well with sterile water, tap water or filtered water. The fourth step is drying. Before storing and after disinfecting, the inner channels and insertion tube should be rinsed with alcohol and dried with forced air. The final step is storage. The endoscope should be stored in such a way that recontamination is avoided and drying is promoted (hanging vertically is an option).
Sadly, inadequate compliance exists with respect to reprocessing endoscopes. Sometimes the claims regarding the usage of the sterilants and disinfectants of the scientific literature and recommendations differ as that on the manufacturer’s label. An instance of the difference in claims is the time required to achieve a high level disinfection with 2% glutaraldehyde. The efficacy of their germicide formulations in the most awful case conditions and the presence of organic soil is tested by the manufacturers under the FDA requirements. The organic loading represents the soil in which the device is disclosed during genuine use and in the absence of cleaning, it will on the device.
These rigorous tests are developed to ensure a margin of safety for the test bacteria elimination by ensuring that the conditions for germicide contact are complete, if the most complex disinfectant areas are immunized to break in, in the absence of cleaning.
Before the chemical disinfection can be done at 20 C for 20 min, that is, 4-6 log10cfu is to be reduced, it is necessary that the reduction of the levels of M. tuberculosis should be done by minimum 8 log10cfu with cleaning, that is, 4 log10cfu is to be reduced. According to the above information, it is suggested by approximately 14 organizations, which are operating globally, in their authorized endoscope-reprocessing instructions that in order to attain high level of disinfection, a contact should be made at 20 C for 20 min with 2% glutaralehyde, or 20 min exterior of the United States, but simultaneously it contradicts with the manufacturer’s suggestions, provided by them on the tag.
It is crucial to accentuate that cleaning, which is an important phase in the process of disinfection, is not included in the FDA tests. In order to remove all the vegetative bacteria effectively, contact is to be made for 20 min with 2% glutaralehyde in the cleaning phase.
Inactivation of Creutzfeldt-Jakob disease (CJD) agent.
It was found that in the United States one person in a million is effected by CJD, which is a degenerative disease in humans, found every year in the same ratio [35]. A proteinaceous infectious agent or prion could be the reason of this disease. There is a relation between CJD and other human transmissible spongiform encephalopathies (TSEs), including, kuru (also known as eradicated), Gertsmann-Straussler-Sheinker syndrome (one person in 40 million, single year), and fatal insomnia syndrome (one person in 40 million, single year). The physical decontamination and conventional chemical methods were shown an odd confrontation, demonstrated by the agents of TSEs and CJD. There are two reasons behind, one is that the sterilization procedures and the conventional disinfection, which do not inactive the CJD agents, and the other one is the outcome of CJD, which is consistently disastrous. Since many years the disinfection and sterilization processes of the CJD prion remained contentious and unadventurous.
The prevalent recommendations incorporate inactivation data as well as utilize infectivity of human tissue, efficacy of eradicating proteins by cleaning, and epidemiological studies regarding prion transmission. Scientific data explicates that; unique prion reprocessing should be applied to the crucial devices (for instance, surgical equipment) as well as semi-crucial devices which are infected by high-risk tissues (for instance, spinal cord, eye tissues, or brain) pertaining to patients with high-risk (for instance, CJD and other identified prion diseases).
In an instance where high-risk patients, crucial or semi-crucial medical paraphernalia, and high-risk tissues are incorporated then it is appropriate to pursue following methodologies: cleaning the equipment and sterilizing it by means of combining sodium hydroxide with autoclaving (for instance, submerge it in NaOH for one hour, after that remove it and thoroughly rinse it with water, finally for autoclaving shift it to a particular open pan for one hour [on 121 centigrade in gravity displacement sterilizer or on 134 centigrade in porous prevacuum sterilizer)]; after that autoclaving on 134 centigrade in prevacuum sterilizer for eighteen minutes; or autoclaving on 132 centigrade in gravity displacement sterilizer. In the sterilizer, the temperature in any point of time must not increase from 134 centigrade due to the fact that as temperature augments the efficiency of autoclaving diminishes (for instance, to 136 centigrade or 138 centigrade). The medical paraphernalia which has been infected by prion and is complicated to sanitize then it should be disposed. In reprocessing, flash sterilization (for instance, at 132 centigrade steam sterilizing an uncovered paraphernalia for three minutes) must not be implemented. In order to lessen environmental contamination, surfaces which are not crucial environmentally must be wrapped by means of plastic papers; hence, when infected by high-risk tissue, then the paper must be adequately disposed. Those surfaces which are not crucial environmentally (for instance, laboratory surface) and are infected by high-risk tissue must be sanitized and after that the area must be decontaminated through a dilution of 1:10 hypochlorite solution.
Antibiotic-resistant bacteria, bioterrorism agent, and emerging pathogen.
Infection-control experts along with general populace are becoming concerned regarding the emerging pathogens. Significant pathogens entail Escherichia coli O157:H7, hepatitis C virus, multidrug-resistant M. tuberculosi, nontuberculosis mycobacteria (or instance, Mycobacterium chelonae), Cryptosporidium parvum, HIV, rotavirus, Helicobacter pylori, and human papillomavirus. Furthermore, latest studies and papers have contemplated on the biological terrorism’s prospective nature. CDC has segregated numerous agents in “high priority” class due to the act that they are swiftly transmitted from one person to another; they can spur higher rates of mortality, and their identification amidst a populace can effortlessly instigate social disruptions and public fright. The prominent of such agents are, Yersinia pestis (plague), Francisella tularensis (tularemia), arenaviruses (Junin [Argentine hemorrhagic fever] and Lassa [Lassa fever]), Bacillus anthracis (anthrax), variola major (smallpox), filoviruses (Ebola and Marburg [hemorrhagic fever]), and other associated viruses.
Dictated by uncommon omissions (for instance, human papillomavirus), inclination of the above stated pathogens to sterilants and chemical disinfectants have been contemplated; furthermore, every single pathogen (surrogate microbes, like vaccinia pertaining to variola, Bacillus atrophaeus [previously Bacillus subtilis] pertaining to B. anthracis, and feline calicivirus pertaining to Norwalk virus) have been deduced as inclined to the prevalent accessible sterilants and disinfectants.
The customary disinfection and sterilization methodologies pertaining to patient-care paraphernalia (mentioned in this paper) are apposite for disinfection or sterilization of equipment or a device which is infected by blood or any body fluid of a patient who has been identified to be infected by emerging pathogens, bioterrorism agents, or bloodborne pathogens, with the omission of prions (refer to preceding section). In the methodologies of disinfecting, sterilizing or cleaning, there is no necessity of alterations. Additionally, no relevant information exists which can express that the antibiotic-resistant bacteria (for instance, Enterococcus faecium a vancomycin-resistant, M. tuberculosis a multidrug-resistant, and Staphylococcus aureus a methicillin-resistant) are less responsive to the liquid chemical germicide analogous to the antibioticsensitive bacteria on prevalently utilized germicides contact concentration and condition.
Advances in disinfection and sterilization methods.
In the health care sector, new and advance methods have been introduced. For the past number of years these methods of sterilization and disinfection have been used. A type of chemical sterilant named as OPA have been receiving the clearance of FDA at the end of the year 1999. This chemical contains benzenedicarboxaldehyde which is almost 0.55% 1.2. The microbicidal activity has found to be very efficient. Moreover, OPA has been showing a great mycobactericidal performance, it lead to 5 log10in and 5 min being reduced. The result seems to be improved when compared to glutaradehyde. The table 2 below illustrates the benefits and disadvantages of OPA along with its characteristics.
In a recent case, FDA had been able to clear a disinfectant that contained a high level of liquid. This disinfectatnt was superoxidized water that contained chlorine of around 650-675 ppm as estimated. This also contained a fresh sterilization system that uses ozone. Due to data being limited, for assessment of activities of antimicrobial or compatibility of material, these processes have not yet been introduced or have come into practice in USA.
The items of patient care are sterilized in several ways. Some of the methods are, using of steam sterilization, system of acid-immersion, ETO and gas plasma of hydrogen peroxide. The table below illustrates both the benefits and disadvantages of the system
In the year 1987 a new and advance technology of sterilization was patented. It introduced its marketing in USA. The marketing began in 1993 and this technology has plasma as its base, that gas plasma’s included solid, liquid, gas plasma and gas. All the four states of matter. The place from where this gas plasma’s are being generated is a type of deep vacuum which has enclosed chambers. The charged particles are produced through the excitation of gas molecules, this is followed by using of radio frequency or instead microwave energy could be used. Several bacterial spores which are a kind of micro organisms can be inactivated with the help of this process. Different studies have been carried out in against to vegetative bacteria, one of them which include mycobacteria. Others are viruses, yeasts bacterial spores and fungi. To measure how effective the sterilization processes have been various elements would be considered such as lumen diameter and length, salts that are inorganic and other organic materials
CONCLUSION
When properly used, sterilization and disinfection can guarantee the harmless use of noninvasive and invasive medical instruments. The technique of sterilization and disinfection is based on the medical instrument’s planned use: it must be done before use for critical items (which comes in contact with sterile tissue); high-degree disinfection is must for semi-critical items (which comes in contact with non-intact skin or mucous membranes); and low-level sterilization is required for non-critical items (which comes in contact with intact skin). High-level sterilization and disinfection should always be preceded with cleaning and guidelines pertaining to sterilization and disinfection should be adhered to strictly.
ENGINEERING ADHESIVES FOR REPETITIVE STERILIZATION
Introduction
Various sterilization techniques have been employed to disinfect medical instruments during the last four decades. The nature of materials used for manufacturing of these devices during the 60s and 70s required that very careful development of sterilization methods. These materials included glass, metal and rubber in general. Subsequently, newer materials were introduced for manufacturing of these devices as they became better performing and intricate. The older materials have been replaced with new materials which include thermoplastics and thermoset. Moreover, the methods used for assembling the medical devices have been modified also.
The previous medical devices were manufactured by using those methods which were beneficial to the substrates being used. These methods included molding, mechanical fastening or machining. These materials and joining methods used in manufacture of earlier medical devices were easily able to endure various sterilization methods which even included some rigorous techniques.
Progress in contagious diseases along with high performance sterilization devices required a change in the fabrication and assembling techniques of these devices. Specifically, the use of plastics in these devices showed the way to new assembly methods and new issues for resistance to sterilization. Adhesives became the automatic choice for many manufacturers of sterilization devices for a variety of reasons which include:
Capability to bond a range of substrates
Capability to seal and bond
Capability to fill up large gaps
easily automated
Medical devices’ classification comprises of different classifications such as sterile disposables, non-sterile reusable and the modern era’s classification as sterile reusable and resposables. Typical objects such as syringes, oxygenators and catheters are considered as sterile disposables and they were made in such a way that they could only be used for one time. Moreover, sterile disposables are gone through sterilization cycle once or twice before their actual use. Whereas, non-sterile reusables require minimal sterilization requirements and they neither come in to direct blood contact nor with the bodily fluids.
In today’s modern era, normally surgeries do not required incision in patient’s body and insertion of medical instruments. This methodology has given birth to the medical devices known as sterile reusables and responsables as they also help in cost reduction through their re-use. Endoscopes and laproscopes are mainly considered as sterile reusables, whereas, sterile resposables are devices which were initially designed for one time use, but now, they are considered for re-use also, and for both the afore-mentioned devices, repeated sterilization is required. Sterilization method, duration of exposure and the sterilization cycle requirement is based on the type of device being sterilized. Moreover, autoclaving, hydrogen peroxide and chemical immersion are the most likely methods that would be used for the sterilization because of their quick turn-around, advantageous and low toxicity.
Sterilization Methods
The method of eliminating all the traces of living organism from medical instruments, making it sure that they are suitable for human use through heat, chemicals and radiations is referred to as sterilization. Most commonly used sterilization methods are briefly defined in Table I. It is most likely that the methods defined below would be used for the sterilization of reusable/resposable medical devices under typical exposure to temperature.
The biggest challenge which the manufacturers have to tackle is created because of the amalgamation of moisture, pressure and temperature as approximately 80% of the medical devices involve a sterilization method known as Autoclaving. Substrates and joining procedures which are versatile and user friendly must be adopted by the manufacturers, to grasp in most meticulous environments. Under meticulous environments, materials that have advance resistance like autoclaving have been started to get developed by the suppliers of plastic. Like polysulfone and polycarbonate that have specialty grades can be obtained commercially.
Adhesives
Approximately thirty years have been passed since the market started utilizing adhesives. However there are numerous adhesives are offered from the industries but biocompatibility compliance is not possessed by all.
In order to assemble the medical devices urethane and epoxy adhesives, dual UV moisture curable silicone, light curing acrylic, light curing cyanoacrylate and cyanoacrylate are utilized commonly. Normally, in comparison with other methods for assembling medical devices many benefits have been offered by adhesives which include abilities that when it is incarcerated between two substrates it generate a hermetic seal, transversely a bondline stress is allocated in an even way, it has ability to generate bond between the materials that are not similar and large gaps can be filled.
Cyanoacrylate adhesives are the molecules which are polar and linear and they have to pass through an anionic polymerization reaction. Significantly over every surface, moisture or base which is weak in nature is present which prompt the reaction so that the linear chains can be formed. As a stabilizer, weak acids are introduced so that the products do not lose their liquid form. Cyanoacrylate formulations that have disparities in their resistance in temperature, strength properties, cure times and viscosities are also present in numerous varieties.
When Cyanoacrylates are cured they make thermoplastic resins. Numerous limitations in performance were pointed out with formulation alterations, by Eastman Kodak in 1950, when cyanoacrylate resins was introduced for the commercial use initially. Peel strengths and impact which is low, solvent resistance that is lower to moderate has been typically applied by Cyanoacrylates that are based upon the standard unfilled ethyl monomer and the maximum limit of temperature while operation reaches 160 to 180°F. To deal with the initial restraints, specialty formulations are now present that includes for peel strengths and enhanced impact, rubber toughened cyanoacrylates are available, for the cure under environment which has low acidity/humidity and rapid fixture, surface insensitive formulations are present, for minimized frosting, products with low bloom/odor are available and products whose temperature remain up to 250°F while continuous operations are also present.
The pace in the cure is not the only outcome of the considerable development in the accelerator and primer formulations but it has also fastened the capability to bond the plastics which are “hard to bond”, this has been attain beside the technology of ethyl cyanoacrylate. Over the “dead” substrates, reactive species have been deposited by solvent-based systems called primers. Bond strength rises up extensively due to these reactive species for the materials like acetal homopolymer, fluoropolymer, polypropylene and polyethylene as they do not bond easily.
The results through sterilization methods which contain many disparities have been obtained from the examination of cyanoacrylate adhesives. Normally, Cyanoacrylate adhesives are exposed to endure and hydrogen peroxide is involved with (50) cycles of liquid sterilization. Adding to it, resistance in a temperate ratio has been exhibited to autoclave exposure by cyanoacrylate adhesives where some ethyl grades which possesses 100% expertise of their original power goes to be exhibited to (50) autoclave cycles. In order to maintain the strength of bond, cyanoacrylate adhesives are considered as critical aspect, which are followed by the substrates’ assortment while the revelation of autoclave as moderate to high level strength has been offered by them including the steam environment, pressure, rigorous temperature is endured by substrates.
A thermoset resin is formed as a result of its exposure in the light which got suitable intensity and wavelength while through a free radical reaction of light curing acrylics. The viscosities in which light curing acrylic adhesives for example cyanoacrylates are obtainable starts from a lower range (~50cP) to thixotropic gels. Moreover, the resins which are in final cured from vary from soft flexible resins to hard resins which look like glass as they are light curing adhesives.
For the treatment of any adhesive the light reaching fully to the bond line is the most important dispensation key for acrylic adhesives that are the remedial of light otherwise the adhesive which comes under the shadow will not be cure properly. Approximately all the acrylic systems cure the adhesives with the maximum deepness of” 0.5”. The instruments need in the process of the product is another important point to take into consideration when selecting a light cure adhesive.
For the occurrence of result in polymerization light curing adhesives need precise radiant energy that is light energy. As this process is very dangerous therefore, the adhesive with the apposite light source are being coordinated by the end user. Acrylic systems that are typically low in intensity have the standard price of $1000 on the other hand the systems with high intensity can run into the tens of thousands of dollar so the manufacturers of adhesives are suggested to use appropriate system.
Vital benefits of quick fixture are accessible by the light curing acrylic technology for example as little as 5 seconds for select joints, subsequent exposure and this will help in decreasing the work in process (WIP). The broad range of substrates can be cured by the newly designed light curing acrylic formulations and it also clear bond line in a yield when applied in slender sections. The light curing acrylics are improved than that of cyanoacrylate adhesives because of the final resins are thermo set plastics, thermal, chemical and environmental resistance.
Extensively unstable performances followed by the autoclave revelation are also offered by the light curing acrylic adhesives, they also diverge in the preservation of bond strength following formulation based on the exposure, , substrates chosen and preliminary strengths attained. According to the testing 50% or less of initial strengths following fifty autoclave cycles are maintained by the light curing acrylic adhesive.
The benefits of both cyanoacrylate technology and light curing acrylic technology were merged in 1998 in United States and a new technology was commenced. Light curing cyanoacrylates are ethyl based products which have photo initiators in its formulation photo initiators were added. The outcome we get from this product is quick fixture and it also cures the shadowed areas. In general physical performance characteristics are comparable to those attain with a traditional cyanoacrylate because the light curing cyanoacrylates are ethyl monomer based. There are some more advantages given by the new technology for instance, as the exposure of uncured cyanoacrylate can be immediately cured by ultraviolet and/or visible light the blooming/frosting will be decreased. The maximum of 0.010 inches can be increased the deepness of cure over the traditional cyanoacrylate and and compatibility with primers for “hard-to-bond” plastics. Light curing cyanoacrylates would be predictable to execute correspondingly to standard ethyl cyanoacrylates following sterilization exposure including autoclave.
The plastic polymers are formed when the silicone adhesives are cured and it is similar to polyurethane adhesives, however no unbending segments are possessed by silicon so it demonstrate lower cohesive strength and the strength of the polymer itself. There are many types of silicon available including one part moisture care, one part heat cure, and one part dual moisture and light cure formulations. Eventhogh there is the existence of two part silicon in industries, the system be unsuccessful in the biocompatibility screening due to catalyst used in such materials. The moisture curing silicon has limited use in the medical device market because of its primary characteristics. The manufacturers also look for the substitutes for the quic fixture and cure in order to evolve by-product like acetic acid with in 24 hours. The utilization of double curing systems which act in response at first to light and then moisture cure provide cure-on-demand fixture strength followed by full cure up to 72 hours later.
Because of the inferior potential cohesiveness of the polymer, the measurement of the sterilization resistance of silicone adhesives is usually done on the bulk polymer. A minor impact on the percent elongation of the adhesives, however, an around 60% reduction in tensile strength was noted during the examination of dual light cure/moisture silicone cements subsequent exposure to fifty (50) autoclave cycles was performed.
Epoxy adhesives cure to give out thermoset plastics, similar to the prior discussed light curing acrylic adhesives. A catalyst, for example, an amine or mercaptan initiates ring opening of an epoxide group by means of which the polymerization reaction takes place. The availability of room temperature and heat curing one and two part systems is positive. Epoxies present better chemical environmental and thermal resistance because of their capability to crosslink. Epoxies are made utilizable for deep section potting of medical apparatus and needle manufacturing due their capability to unite a broad range of substrates along with their greater gap filling abilities.
The utilization of epoxies on temperature responsive components must be intimately observed due to the fact that they cure via an exothermic reaction (releasing heat in curing). The epoxy has inflexible character when cured, which characteristically end up in low peel strengths, thus making it a second prospective disadvantage of their utilization.
In the availability of one and two part formulations, Polyurethane adhesives are similar to epoxies. The polyol and isocyanate, which are the two major formulation components, react to structure hard and soft sections in the resultant polymer, thus forming a urethane linkage. The exclusively flexible, however strongly cured material is contributed by segments like these. Polyurethane adhesives form thermoset resins once they are cured, therefore displaying fine chemical and environmental resistance, alike various formerly stated chemistries. On the whole, the thermal stability of cured polyurethanes is comparatively lesser than that of cured epoxies, which is, however, significant to notice.
Even though the polyurethane adhesives are substrate flexible, at times they require a surface primer to improve the reactivity of the material that is to be glued. For effective preparation of the surface for the glue, most primers need long on part times. Another downside of using polyurethane adhesives is their innate vulnerability to moisture. Too much dampness on a fraction or in any of the components causes a reaction, which leads to the production of carbon dioxide, follow-on in bubbles in the final product. The superb chemical and thermal properties of epoxy and urethane are one reason why they are often chosen for application. Due to this resistance adhesives are appropriate contenders for the latest medical devices; sterile reusables and reposables. Since there is prospective of continual autoclaving exposure, it is imperative that the producers of reuasable and resposable devices use the adhesives which can tolerate high temperatures and high steam pressure conditions.
Autoclave Resistant Epoxy & Polyurethane Adhesives
The adhesives that were generally used for the production of disposable and reusable medical tools, mainly cyanoacrylates and light curing acrylics, showed low to modest resistance to autoclaving. Lately a research was carried out to find the adhesives that can be used be used for repetitive autoclave sequences whilst having the fringe of ease of use, substrate adaptability and excellent performance. Five adhesives were chosen to be assessed as prospectives to be used for processes that require continuous autoclave exposure; three of the products were epoxy-based and two were polyurethane-based. In the study five substrates evaluated included polycarbonate (PC), stainless steel (S/S), glass, polyvinyl chloride (PVC) and polyetherimide (PEI). Each of them, except for PC, was used for assemblies, divulged to ten and twenty-five repeated autoclave rotations. The sterilization exposure control incorporated six minutes of prevac sterilization at 132°C allowing a three minute period to dry in between the cycles.
The results showed that the epoxy adhesives with low and medium consistency gave great results after ten and twenty five autoclave cycles; there strength remained close to the original. The polyurethane adhesives with medium and low viscosity showed strengths pretty close to the initial. Most of the assemblies pertaining to stainless steel showed adhesive failure.
The three epoxy adhesives executed very well after the twenty five autoclave cycles, upholding their strengths close to the initial. However, after the autoclave exposure, the medium and low viscosity polyutherane adhesives showed a vast decrease in potency. Most of the assemblies that included the epoxy adhesives demonstrated downfall of the substrate; on the other hand, the urethane assemblies presented both, adhesive and cohesive failure.
The five adhesives were also tested on PC lapshear samples. Because of the different qualities of plastic used, the testing with PC was restricted to up to ten autoclave cycles. The epoxy and urethane adhesives with low density showed strengths that were very close to that at the start, while the strengths of the substrates increased in most of the cases. Other adhesives showed a large loss of strength after sterilization ans adhesive failure.
Testing the five adhesives on PVC lap shear showed that overall the assemblies withheld 100-350% of their strengths subsequent to the autoclave exposure. Moreover, all of the autoclaved variety displayed a vast increase in length of the substrate, during the test. This might be one of the causes of the slight melting of the plastic, given that some qualities of PVC have melting temperatures as low as 132°C.
Additionally, the chosen adhesives were also examined on PIE lap shear specimens. At the end it was only the low viscosity samples that retained strengths close to the initial, majority of the epoxy assemblies demonstrated failure successive to autoclave exposure. The urethanes with medium viscosity retained strengths close to and more than the original. Assemblies with urethane showed a blend of adhesive and cohesive and failure.
Summary
It was concluded that adhesive resistance to continual autoclave cycles depends upon adhesive formulation and the substrate being used. Overall, it was deducted that majority of the epoxy and urethane adhesives tested can resist up to twenty five continuous autoclave cycles on a number of different substrates, counting glass, metal and plastic. However, the patent low viscosity epoxy, along with the off-white moderate viscosity urethane adhesives showed strengths of the substrates ranging from70% of the original, to in excess after twenty five autoclave cycles. As adhesive performance is dependent on the substrate, it is best execution is completely assessed to guarantee that the blend of adhesive and substrate are harmonizing with the constant autoclave environments, especially the autoclave.
Careful screening of substrates (like PVC, Glass, and PC) should be conducted in order to ascertain their capability to withstand the conditions in which they will be put under operations for frequent autoclave sterilization. Even before the usage of substrate in resposable or reusable device, close interaction should be maintained with the substrate supplier regarding the evaluation of weakening or/and deformation of substrate.